Online UPS · Three Phase In / Out · Isolation Transformer

E-Power Series

An industrial-grade three-phase online UPS from 10 to 800 kVA with isolation transformer, full DSP control, 0.9 output power factor and N+X parallel redundancy up to 6 units.

Grid InSags · surges · harmonics
UPS Out230 V pure sine
E-Power Series Online UPS
3Φ In · 3Φ Out
Choose Capacity:
Capacity
10–800 kVA
Efficiency
Up to 94%
Transfer Time
0 ms
Output Power Factor
0.9
Parallel
Up to 6 units, N+X
Battery
384–600 VDC
Ideal For:Data CentresHeavy IndustryHospitalsLarge Buildings

Key Features

  • Isolation TransformerNoise rejection and strong load protection.
  • Full DSP ControlFully digital for a stable, reliable system.
  • 0.9 Output Power FactorBetter matched to modern loads.
  • N+X Parallel RedundancyUp to 6 units with automatic fault isolation.
  • Strong Overload Capability110% for 60 min, 125% for 10 min, 150% for 1 min.
  • Power Walk-In and Generator ModeReduces the generator size you need.
  • Backup-Time PredictionSmart battery management with periodic self-test.
  • EPO and Dry ContactsEmergency power off and remote monitoring.

Specifications

10–80 kVA Models

Specification10 kVAEP1020 kVAEP2030 kVAEP3040 kVAEP4060 kVAEP6080 kVAEP80
Input
Input Voltage Range380 / 400 / 415 VAC (−25% / +20%), 3Ph + N + PE
Frequency Range50 / 60 Hz ± 5%
Input Power Factor> 0.97 with filter
Output
Rated Capacity10 kVA / 9 kW20 kVA / 18 kW30 kVA / 27 kW40 kVA / 36 kW60 kVA / 54 kW80 kVA / 72 kW
Output Voltage380 / 400 / 415 VAC ± 1%
Output Frequency50 / 60 Hz ± 0.05%
Waveform THD< 3% linear load
Crest Factor3 : 1
Efficiency88% to 90.5% depending on model
Overload≤ 110%: 60 min · ≤ 125%: 10 min · ≤ 150%: 1 min, then bypass
Bypass
Voltage Protection Range+20% / −40%, adjustable
Frequency Protection Range± 10%, adjustable
Battery
DC Voltage384 VDC (360–384 VDC)
Transfer Time0 ms, line to battery
General
CommunicationDry contact, RS232, RS485 · SNMP card optional
Net Weight148 kg163 kg230 kg255 kg386 kg426 kg
Operating Temperature0–40 °C
Noise< 60–65 dB
StandardsIEC / EN 62040-1, -2 · IEC 62040-3 · IEC / EN 62477-1

100–800 kVA Models

Specification100 kVAEP100120 kVAEP120160 kVAEP160200 kVAEP200300 kVAEP300400 kVAEP400500 kVAEP500-12P600 kVAEP600-12P800 kVAEP800-12P
Input
Input Voltage Range380 / 400 / 415 VAC (−25% / +20%), 3Ph + N + PE
Frequency Range50 / 60 Hz ± 5%
Input Power Factor> 0.97 with filter
Output
Rated Capacity100 kVA / 90 kW120 kVA / 108 kW160 kVA / 144 kW200 kVA / 180 kW300 kVA / 270 kW400 kVA / 360 kW500 kVA / 450 kW600 kVA / 540 kW800 kVA / 720 kW
Output Voltage380 / 400 / 415 VAC ± 1%
Output Frequency50 / 60 Hz ± 0.05%
Waveform THD< 2% linear load
Crest Factor3 : 1
Efficiency92% to 94% depending on model
Overload≤ 110%: 60 min · ≤ 125%: 10 min · ≤ 150%: 1 min, then bypass
Bypass
Voltage Protection Range+20% / −40%, adjustable
Frequency Protection Range± 10%, adjustable
Battery
DC Voltage384 VDC (360–408 VDC) · 480 / 600 VDC on the largest models
Transfer Time0 ms, line to battery
General
CommunicationDry contact, RS232, RS485 · SNMP card optional
Net Weight625 / 1300 kg685 / 1450 kg980 / 1645 kg1030 / 1715 kg1560 / 2395 kg1640 / 2510 kg3510 kg3950 kg4950 kg
Operating Temperature0–40 °C
Noise< 65–70 dB
StandardsIEC / EN 62040-1, -2 · IEC 62040-3 · IEC / EN 62477-1

* 100–400 kVA models come with a 6-pulse or 12-pulse rectifier; weights shown as 6P / 12P. Optional: harmonic filter, SNMP adapter, LBS cables, battery temperature sensor, bypass current-sharing inductor. Specifications may change as products are improved.