XP Series
A wide-range tower UPS with true double conversion and up to 93% efficiency, available as a standard unit with built-in batteries or a long-run unit for external banks.

- Capacity
- 1–10 kVA
- Efficiency
- Up to 93%
- Transfer Time
- 0 ms
- Input Power Factor
- ≥ 0.99
- Input Window
- 110–300 VAC
- Versions
- Standard or Long-Run
Key Features
- True Double ConversionClean, regulated power at all times.
- Up to 93% EfficiencyLower running cost on larger models.
- Wide Input Window110–300 VAC keeps you off battery longer.
- Standard or Long-RunBuilt-in batteries or an adjustable charger for external banks.
- Frequency Converter ModeRun 50 Hz or 60 Hz equipment from either supply.
- ECO ModeEnergy saving on 1–3 kVA models.
- Generator CompatibleStable on diesel generator supply.
- Smart MonitoringRS-232 / USB software with optional SNMP.
Specifications
| Specification | 1 kVAXP 1K | 2 kVAXP 2K | 3 kVAXP 3K | 6 kVAXP 6K | 10 kVAXP 10K |
|---|---|---|---|---|---|
| Input | |||||
| Nominal Voltage | 208 / 220 / 230 / 240 VAC (110–127 VAC versions on 1–3 kVA) | ||||
| Input Voltage Range | 110–300 VAC at 50% load · 160–280 VAC at 100% load | 110–300 VAC at 50% load · 176–300 VAC at 100% load | |||
| Frequency Range | 40–70 Hz | 46–54 Hz or 56–64 Hz | |||
| Input Power Factor | ≥ 0.99 at nominal voltage | ||||
| Output | |||||
| Output Voltage | 208 / 220 / 230 / 240 VAC ± 1% | ||||
| Frequency, Battery Mode | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz | 50 / 60 Hz ± 0.1 Hz | |||
| Waveform THD | ≤ 3% linear · ≤ 6% non-linear | ≤ 3% linear · ≤ 5% non-linear | |||
| Crest Factor | 3 : 1 | ||||
| Transfer to Battery | 0 ms | ||||
| Transfer to Bypass | 4 ms (typical) | 0 ms | |||
| Efficiency | |||||
| AC Mode | 88% | 89% | 90% | 92% | 93% |
| Battery Mode | 83% | 87% | 88% | 90% | 91% |
| Battery | |||||
| Standard Unit | Built-in 12 V 9 Ah batteries | ||||
| Batteries, Standard Unit | 2 | 4 | 6 | 16 / 20 | 16 / 20 |
| Recharge Time | 4 hours to 90% | 9 hours to 90% | |||
| Long-Run Charger | 1 / 2 / 4 / 6 A, adjustable | ||||
| General | |||||
| Display | LCD with load, battery, mode and fault indicators | ||||
| Communication | Smart RS-232 / USB · SNMP card optional | ||||
| Noise | < 50 dB at 1 m | < 55 dB | < 58 dB | ||
| Net Weight, Standard Unit | 9.8 kg | 17 kg | 27.6 kg | 61–74 kg | 66–76 kg |
* Long-run models are available for 208–240 VAC systems. Derate to 80% in frequency-converter mode or at 208 VAC output. Specifications may change as products are improved.